Archive
Search

You can search published articles.

Journal Information

Online ISSN
1305-3124

Established
1993

Editors-in-Chief
​Cihat Şen, ​Nicola Volpe

Editors
Cecilia Villalain, Daniel Rolnik, M. Mar Gil

Managing Editors
Murat Yayla

Statistics Editor
Resul Arısoy

Sonographic cervical length and biochemical markers in spontaneous preterm birth(SPTB) up to 14 days from sampling

Marija Hadzi Lega, Ana Daneva Markova, Milan Stefanovic

Article info

Sonographic cervical length and biochemical markers in spontaneous preterm birth(SPTB) up to 14 days from sampling. Perinatal Journal 2014;22(Suppl):SE5 DOI: 10.2399/prn.14.S001084

Author(s) Information

Marija Hadzi Lega1,
Ana Daneva Markova1,
Milan Stefanovic2

  1. University Clinic of Gynecology and Obstetrics- Skopje MD
  2. University Clinic of Gynecology and Obstetrics- Nis SR
Correspondence

Marija Hadzi Lega, University Clinic of Gynecology and Obstetrics- Skopje MD,

Publication History
Conflicts of Interest

No conflicts declared.

Objective
The aim of this study was to determine the relationship between sonographic cervical length, fetal fibronectin(fFN), phIGFBP-1 (Actim partus test), cytokines (IL-6,IL-2R and TNF-alpha) and spontaneous preterm birth(SPTB) up to 14 days from sampling.
Methods 
Patients were recruited in period of 6 months from September 2013 untill March 2014 with symptoms or complaints suggestive of preterm labor Consenting women were treated according to usual hospital protocol, with addition of vaginal swabs taken for fetal fibronectin, phIGFBP-1(Actim partus test) and cervicovaginal IL6,IL2R and TNF-alpha. The outcome variable was occurrence of preterm delivery within 14 days from the day of hospital admission.
Results
Thirty six patients (62.07%) were delivered within 14 days from admission. The fetal fibronectin test is a significant predictor of preterm delivery. Patients with a positive fetal fibronectin test have an OR of 6.429 (95%CI 1.991-20.758) to deliver prematurely. The patients that gave birth within 14 days of admission were also statistically more likely to have a positive phIGFBP-1 test (p=0.02). All but one pregnant women that remained pregnant after 14 days of admission had a serum level of IL-2R below 500 U/mL and the difference in concentrations between the two groups is statistically significant (p=0.044). The patients that were delivered within 14 days of admission in our study group had an average cervical length of 18.78±5.8mm, which is significantly lower than the average cervical length (23.87±6.36) of patients that remained pregnant after 14 days (p=0.0028). Our results indicated that the cervical length significantly correlates with the concentration of IL-6 in the CVF (Spearman’s coefficient R = -0.382, p<0.05), i.e. there is a negative indirect correlation between the two parameters, which means that increased IL-6 concentrations in the CVF mean shortening of the cervix and vice-versa. Cervical length also correlated with a positive phIGFBP-1 test i.e. patients with a positive test had an average cervical length of 18.5±4.63mm, which is significantly lower than patients with a negative test – 23.43±7.39mm (p=0.003).
Conclusions
The studied biochemical markers ion our study were only moderately successful in the prediction of preterm delivery. Further research is required in terms of the evaluation of cost-benefit of using such test to prevent subsequent unnecessary interventions in the low-risk group, as well as achieve the benefits from such intervention in the high-risk groups of patients.
Keywords

Preterm labor, cervical length, predictive value

-